CITECT SCADA LATEST VERSION LICENSE
WARNING: If the Runtime Dynamic Point Count is ever greater than the license’s point count, a license error will occur and Citect will shutdown. The runtime Dynamic point count in your project is often much lower than your total variable count. Dynamic Runtime Count This Presentation is © 2005 – 2007 Citect Pty Ltdġ200 Variable Tags defined in your project may not require a 1200 point license. If you use a PLC ( say an M340) based tag and write it to a local variable, the local variable will be counted as a “Dynamic Runtime Tag” the first time it is evaluated as an expression.

Vijeo Citect SCADA Local Variables / Disk Variables Citect SCADA “Local variables”, “Disk IO variable tags” and “Memory Variable Tags” can be counted against the “Dynamic Runtime Tag” count if they contain a value that originated in a PLC. If a CiCode file uses a variable tag several times, the variable tag will only be counted once. If five alarms use the same tag, the variable tag will only be counted once. If two trend tags use the same variable tag, it will be counted once. There are a few important implications of this method of “Dynamic” tag counting: Two tags that use the same PLC address will be counted twice.
CITECT SCADA LATEST VERSION FULL
1 Citect SCADA Pricing Synergist SCADA Inc Version 1.4 – October 3, 2012Ĭhange Name Date 1 This Presentation is © 2005 – 2007 Citect Pty LtdĢ #1 Rule: Always work with your local Schneider Sales Representative to properly price and license your Vijeo Citect SCADA licensesģ USB License Keys Contain License CALs “Client Access Licenses”ĬALs are shared across the network to any server that require it Typical CALS: Full License Required to run an IO / Alarm / Report / Trend server Includes 1 client license which can run locally on the server (Or can be used by another computer if the Computer Setup Wizard Full License box is checked) Client Control Client View Only Client Web / Internet Control Client Web / Internet View Only ClientĤ SCADA Point Count Maximum number of runtime variable tags that can be used by your system Memory or Disk variable do NOT count against your pointsĬitect / Vijeo Citect 7.0 and higher use a “dynamic-point licensing” model (See Knowledgebase article Q4939 ) Citect uses the Dynamic Runtime count of all tags used Alarms Trends Reports Events Page Tags Super Genies TagRead() and TagWrite() Cicode functions DDE, OPC, ODBC, ADO or the CTAPI (Historian) In Vijeo Citect SCADA 7.0+ the “Dynamic Runtime Tag” count is now tag based not PLC address based.